ABC Cable-0.6/1KV
Grand Cable
Availability: | |
---|---|
Application
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
Applicable Standard
NF C 33-209
Cable Construction
Phase Conductor (AAC Compacted)
All conductors shall be constructed to IEC 61089. The properties of the Aluminium wires before stranding shall be as below.
Tensile strength not less than | 90 N/mm2 |
Resistivity at 20°C not exceeding | 0.02845 ohm/mm²/m |
Netural Conductor (AAAC Non-Compacted)
The neutral shall be an All-Aluminium-Alloy conductor composed of wires drawn from rod, which is manufactured in a continuous casting and rolling procedure. The properties for the individual wires before stranding shall be
Tensile strength not less than | 278 N/mm² |
Resistivity at 20°C not exceeding | 0.0328 ohm/mm²/m |
Insulation
The Insulating Material shall be of black weather resistant cross linked thermosetting polyethylene (XLPE) conforming to IEC60502/IEC60811/ ASTM D 1603 and it shall be fully pressure extruded on the bare conductors of the phases / street lamp / neutral.
Dimenison Characteristics
Article | Unit | Offered Value |
ABC Twisted cable 3x35 mm² + 1x54,6 Alec | ||
Standard | NFC 33209 or equivalent | |
Material | ALUMINIUM | |
section | mm² | 50 |
number of cores | n | 7 |
Min Diameter | mm | 7.9 |
Max Diameter | mm | 8.4 |
Max Linear resistance of CC at 20°C | Ohm/km | 0.641 |
Breaking load | daN | 620 |
Neutral/support Conductor of | ||
material | ALMELEC | |
section | mm² | 54.6 |
number of cores | n | 7 |
Min Diameter | mm | 9.2 |
Max Diameter | mm | 9.6 |
Max Linear resistance of CC at 20°C | Ohm/km | 0.63 |
Breaking load | daN | 1660 |
Insulating Sheath thickness | mm | 1.6 |
Overall Diameter of cable | mm | 12.3 to 13 |
Application
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
Applicable Standard
NF C 33-209
Cable Construction
Phase Conductor (AAC Compacted)
All conductors shall be constructed to IEC 61089. The properties of the Aluminium wires before stranding shall be as below.
Tensile strength not less than | 90 N/mm2 |
Resistivity at 20°C not exceeding | 0.02845 ohm/mm²/m |
Netural Conductor (AAAC Non-Compacted)
The neutral shall be an All-Aluminium-Alloy conductor composed of wires drawn from rod, which is manufactured in a continuous casting and rolling procedure. The properties for the individual wires before stranding shall be
Tensile strength not less than | 278 N/mm² |
Resistivity at 20°C not exceeding | 0.0328 ohm/mm²/m |
Insulation
The Insulating Material shall be of black weather resistant cross linked thermosetting polyethylene (XLPE) conforming to IEC60502/IEC60811/ ASTM D 1603 and it shall be fully pressure extruded on the bare conductors of the phases / street lamp / neutral.
Dimenison Characteristics
Article | Unit | Offered Value |
ABC Twisted cable 3x35 mm² + 1x54,6 Alec | ||
Standard | NFC 33209 or equivalent | |
Material | ALUMINIUM | |
section | mm² | 50 |
number of cores | n | 7 |
Min Diameter | mm | 7.9 |
Max Diameter | mm | 8.4 |
Max Linear resistance of CC at 20°C | Ohm/km | 0.641 |
Breaking load | daN | 620 |
Neutral/support Conductor of | ||
material | ALMELEC | |
section | mm² | 54.6 |
number of cores | n | 7 |
Min Diameter | mm | 9.2 |
Max Diameter | mm | 9.6 |
Max Linear resistance of CC at 20°C | Ohm/km | 0.63 |
Breaking load | daN | 1660 |
Insulating Sheath thickness | mm | 1.6 |
Overall Diameter of cable | mm | 12.3 to 13 |