AACSR
Grand Cable
Availability: | |
---|---|
Application
AACSR is used as bare overhead transmission cable and as primary and secondary distribution cable. AACSR offers optimal strength for line design, and variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Galvanizesd Steel Core
Aluminum Alloy Wires
Characteristics
Code Name | Stranding | Section | Overall Diameter | Conductor Weight | Rated Strength | Electrical Resistance | |
Aluminum Alloy | Steel | mm2 | mm | kg/km | kN | DC.20°C | |
No. x Φmm | Ω/km | ||||||
PHLOX 37.7 | 9/2.00 | 3/2.00 | 37.7 | 8.30 | 152 | 22.85 | 1.176 |
PHLOX 59.7 | 12/2.00 | 7/2.00 | 59.7 | 10.00 | 276 | 44.15 | 0.882 |
PHLOX 75.5 | 12/2.25 | 7/2.25 | 75.5 | 11.25 | 348 | 55.85 | 0.697 |
PHLOX 116.2 | 18/2.00 | 19/2.00 | 116.2 | 14.00 | 624 | 104.90 | 0.59 |
PHLOX 147.1 | 18/2.25 | 19/2.25 | 147.1 | 15.75 | 790 | 132.80 | 0.467 |
PASTEL 147.1 | 30/2.25 | 7/2.25 | 147.1 | 15.75 | 547 | 79.10 | 0.279 |
PHLOX 181.6 | 18/2.50 | 19/2.50 | 181.6 | 17.50 | 975 | 160.20 | 0.378 |
PASTEL 181.6 | 30/2.50 | 7/2.50 | 181.6 | 17.50 | 672 | 96.30 | 0.226 |
PHLOX 228.0 | 18/2.80 | 19/2.80 | 228.0 | 19.60 | 1225 | 201.00 | 0.3 |
PASTEL 228.0 | 30/2.80 | 7/2.80 | 228.0 | 19.60 | 848 | 120.80 | 0.18 |
PHLOX 288.0 | 18/3.15 | 19/3.15 | 288.0 | 22.05 | 1550 | 249.90 | 0.238 |
PASTEL 288.0 | 30/3.15 | 7/3.15 | 288.0 | 22.05 | 1070 | 151.30 | 0.142 |
PASTEL 299 | 42/2.50 | 19/2.50 | 299.0 | 22.50 | 1300 | 198.50 | 0.162 |
PHLOX 376.0 | 24/2.80 | 37/2.80 | 376.0 | 25.20 | 2200 | 369.30 | 0.226 |
PHLOX 94.1 | 15/2.10 | 19/1.68 | 94.1 | 12.60 | 481 | 77.95 | 0.642 |
PASTEL 412.0 | 32/3.60 | 19/2.40 | 412.0 | 26.40 | 1593 | 223.80 | 0.103 |
PETUNIA 612.0 | 66/3.13 | 19/2.65 | 612.0 | 32.10 | 2245 | 312.60 | 0.0657 |
PETUNIA 865.0 | 66/3.72 | 19/3.15 | 865.0 | 38.10 | 3174 | 430.30 | 0.0465 |
Application
AACSR is used as bare overhead transmission cable and as primary and secondary distribution cable. AACSR offers optimal strength for line design, and variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Galvanizesd Steel Core
Aluminum Alloy Wires
Characteristics
Code Name | Stranding | Section | Overall Diameter | Conductor Weight | Rated Strength | Electrical Resistance | |
Aluminum Alloy | Steel | mm2 | mm | kg/km | kN | DC.20°C | |
No. x Φmm | Ω/km | ||||||
PHLOX 37.7 | 9/2.00 | 3/2.00 | 37.7 | 8.30 | 152 | 22.85 | 1.176 |
PHLOX 59.7 | 12/2.00 | 7/2.00 | 59.7 | 10.00 | 276 | 44.15 | 0.882 |
PHLOX 75.5 | 12/2.25 | 7/2.25 | 75.5 | 11.25 | 348 | 55.85 | 0.697 |
PHLOX 116.2 | 18/2.00 | 19/2.00 | 116.2 | 14.00 | 624 | 104.90 | 0.59 |
PHLOX 147.1 | 18/2.25 | 19/2.25 | 147.1 | 15.75 | 790 | 132.80 | 0.467 |
PASTEL 147.1 | 30/2.25 | 7/2.25 | 147.1 | 15.75 | 547 | 79.10 | 0.279 |
PHLOX 181.6 | 18/2.50 | 19/2.50 | 181.6 | 17.50 | 975 | 160.20 | 0.378 |
PASTEL 181.6 | 30/2.50 | 7/2.50 | 181.6 | 17.50 | 672 | 96.30 | 0.226 |
PHLOX 228.0 | 18/2.80 | 19/2.80 | 228.0 | 19.60 | 1225 | 201.00 | 0.3 |
PASTEL 228.0 | 30/2.80 | 7/2.80 | 228.0 | 19.60 | 848 | 120.80 | 0.18 |
PHLOX 288.0 | 18/3.15 | 19/3.15 | 288.0 | 22.05 | 1550 | 249.90 | 0.238 |
PASTEL 288.0 | 30/3.15 | 7/3.15 | 288.0 | 22.05 | 1070 | 151.30 | 0.142 |
PASTEL 299 | 42/2.50 | 19/2.50 | 299.0 | 22.50 | 1300 | 198.50 | 0.162 |
PHLOX 376.0 | 24/2.80 | 37/2.80 | 376.0 | 25.20 | 2200 | 369.30 | 0.226 |
PHLOX 94.1 | 15/2.10 | 19/1.68 | 94.1 | 12.60 | 481 | 77.95 | 0.642 |
PASTEL 412.0 | 32/3.60 | 19/2.40 | 412.0 | 26.40 | 1593 | 223.80 | 0.103 |
PETUNIA 612.0 | 66/3.13 | 19/2.65 | 612.0 | 32.10 | 2245 | 312.60 | 0.0657 |
PETUNIA 865.0 | 66/3.72 | 19/3.15 | 865.0 | 38.10 | 3174 | 430.30 | 0.0465 |