CU/XLPE/PVC-0.6/1KV
Grand Cable
Availability: | |
---|---|
Application
Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.
Applicable Standard
IEC 60502-1
Characteristics
Voltage Rating Uo/U: 0.6/1 kV
Temperature Rating: Fixed: -15°C to + 70°C Flexed: -15°C to + 50°C
Minimum Bending Radius: Fixed: 12 x Overall Diameter (O.D.)
Cable Construction
Conductor
RE: Class 1 solid copper conductor
RM: Class 2 stranded copper conductor
Insulation
Cross-linked Polyethylene (XLPE)
Filler
PP Rope
Sheath
PVC (Polyvinyl Chloride)
Dimension Characteristics
Nom. Cross-section of conductor | Insulation Thickness | Sheath Thickness | Approx. O.D. | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C |
mm2 | mm | mm | (mm) | kg/km | Ω /km | kV/5min |
2x2.5 | 0.7 | 1.8 | 11.2 | 145 | 7.41 | 3.5 |
2x4 | 0.7 | 1.8 | 12.2 | 185 | 4.61 | 3.5 |
2x6 | 0.7 | 1.8 | 13.2 | 236 | 3.08 | 3.5 |
2x10 | 0.7 | 1.8 | 15.8 | 348 | 1.83 | 3.5 |
2x16 | 0.7 | 1.8 | 17.8 | 487 | 1.15 | 3.5 |
2x25 | 0.9 | 1.8 | 21.2 | 718 | 0.727 | 3.5 |
2x35 | 0.9 | 1.8 | 22.4 | 907 | 0.524 | 3.5 |
2x50 | 1.0 | 1.8 | 25.4 | 1189 | 0.387 | 3.5 |
2x70 | 1.1 | 1.8 | 28.8 | 1642 | 0.268 | 3.5 |
2x95 | 1.1 | 2.0 | 32.6 | 2220 | 0.193 | 3.5 |
2x120 | 1.2 | 2.1 | 36.2 | 2769 | 0.153 | 3.5 |
2x150 | 1.4 | 2.2 | 40.2 | 3404 | 0.124 | 3.5 |
Application
Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.
Applicable Standard
IEC 60502-1
Characteristics
Voltage Rating Uo/U: 0.6/1 kV
Temperature Rating: Fixed: -15°C to + 70°C Flexed: -15°C to + 50°C
Minimum Bending Radius: Fixed: 12 x Overall Diameter (O.D.)
Cable Construction
Conductor
RE: Class 1 solid copper conductor
RM: Class 2 stranded copper conductor
Insulation
Cross-linked Polyethylene (XLPE)
Filler
PP Rope
Sheath
PVC (Polyvinyl Chloride)
Dimension Characteristics
Nom. Cross-section of conductor | Insulation Thickness | Sheath Thickness | Approx. O.D. | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C |
mm2 | mm | mm | (mm) | kg/km | Ω /km | kV/5min |
2x2.5 | 0.7 | 1.8 | 11.2 | 145 | 7.41 | 3.5 |
2x4 | 0.7 | 1.8 | 12.2 | 185 | 4.61 | 3.5 |
2x6 | 0.7 | 1.8 | 13.2 | 236 | 3.08 | 3.5 |
2x10 | 0.7 | 1.8 | 15.8 | 348 | 1.83 | 3.5 |
2x16 | 0.7 | 1.8 | 17.8 | 487 | 1.15 | 3.5 |
2x25 | 0.9 | 1.8 | 21.2 | 718 | 0.727 | 3.5 |
2x35 | 0.9 | 1.8 | 22.4 | 907 | 0.524 | 3.5 |
2x50 | 1.0 | 1.8 | 25.4 | 1189 | 0.387 | 3.5 |
2x70 | 1.1 | 1.8 | 28.8 | 1642 | 0.268 | 3.5 |
2x95 | 1.1 | 2.0 | 32.6 | 2220 | 0.193 | 3.5 |
2x120 | 1.2 | 2.1 | 36.2 | 2769 | 0.153 | 3.5 |
2x150 | 1.4 | 2.2 | 40.2 | 3404 | 0.124 | 3.5 |