H1Z2Z2-K
Grand Cable
Availability: | |
---|---|
Application
DC Cable H1Z2Z2-K acc. to EN 50618, are intended for use in Photovoltaic Power Supply Systems at nominal voltage rate up to 1,5/1,5kV DC.They are suitable for applications indoor and/or outdoor, in industrial and agriculture fields, in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas.They may be installed fixed, freely suspended or free movable, in cable trays,conduits, on and in walls.DC Cable H1Z2Z2-K are suitable for direct burial where the corresponding guidelines for direct burial shall be considered.
Cable Construction
Conductor: Electrolytic tinned copper, finely stranded class 5 in accordance with IEC 60228
Insulation: Halogen-free cross-linked compound
Sheath: Halogen-free cross-linked, flame retardant compound
Insulation & Sheath Color: Red or Black
Dimension characteristics
No. of Cores×Nominal Cross Section | No. of Stranding | Nominal Conductor Diameter | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diamater | Nominal Weight |
No.×mm2 | - | mm | mm | mm | mm | kg/km |
1×1.5 | 30/0.25 | 1.58 | 0.7 | 0.8 | 5.4 | 40 |
1×2.5 | 50/0.25 | 2.04 | 0.7 | 0.8 | 5.9 | 50 |
1×4.0 | 56/0.30 | 2.59 | 0.7 | 0.8 | 6.6 | 70 |
1×6.0 | 84/0.30 | 3.17 | 0.7 | 0.8 | 7.4 | 80 |
1×10 | 78/0.40 | 4.07 | 0.7 | 0.8 | 8.8 | 130 |
1×16 | 128/0.40 | 5.22 | 0.7 | 0.9 | 10.1 | 200 |
1×25 | 199/0.40 | 6.51 | 0.9 | 1 | 12.5 | 290 |
1×35 | 279/0.40 | 7.71 | 0.9 | 1.1 | 14 | 400 |
1×50 | 396/0.40 | 9 | 1 | 1.2 | 16.3 | 550 |
1×70 | 360/0.50 | 10.8 | 1.1 | 1.2 | 18.7 | 750 |
1×95 | 475/0.50 | 12.6 | 1.1 | 1.3 | 20.8 | 970 |
1×120 | 608/0.50 | 14.2 | 1.2 | 1.3 | 22.8 | 1220 |
1×150 | 756/0.50 | 15.8 | 1.4 | 1.4 | 25.5 | 1510 |
1×185 | 925/0.50 | 17.4 | 1.6 | 1.6 | 28.5 | 1850 |
1×240 | 1221/0.50 | 20.4 | 1.7 | 1.7 | 32.1 | 2400 |
Application
DC Cable H1Z2Z2-K acc. to EN 50618, are intended for use in Photovoltaic Power Supply Systems at nominal voltage rate up to 1,5/1,5kV DC.They are suitable for applications indoor and/or outdoor, in industrial and agriculture fields, in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas.They may be installed fixed, freely suspended or free movable, in cable trays,conduits, on and in walls.DC Cable H1Z2Z2-K are suitable for direct burial where the corresponding guidelines for direct burial shall be considered.
Cable Construction
Conductor: Electrolytic tinned copper, finely stranded class 5 in accordance with IEC 60228
Insulation: Halogen-free cross-linked compound
Sheath: Halogen-free cross-linked, flame retardant compound
Insulation & Sheath Color: Red or Black
Dimension characteristics
No. of Cores×Nominal Cross Section | No. of Stranding | Nominal Conductor Diameter | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diamater | Nominal Weight |
No.×mm2 | - | mm | mm | mm | mm | kg/km |
1×1.5 | 30/0.25 | 1.58 | 0.7 | 0.8 | 5.4 | 40 |
1×2.5 | 50/0.25 | 2.04 | 0.7 | 0.8 | 5.9 | 50 |
1×4.0 | 56/0.30 | 2.59 | 0.7 | 0.8 | 6.6 | 70 |
1×6.0 | 84/0.30 | 3.17 | 0.7 | 0.8 | 7.4 | 80 |
1×10 | 78/0.40 | 4.07 | 0.7 | 0.8 | 8.8 | 130 |
1×16 | 128/0.40 | 5.22 | 0.7 | 0.9 | 10.1 | 200 |
1×25 | 199/0.40 | 6.51 | 0.9 | 1 | 12.5 | 290 |
1×35 | 279/0.40 | 7.71 | 0.9 | 1.1 | 14 | 400 |
1×50 | 396/0.40 | 9 | 1 | 1.2 | 16.3 | 550 |
1×70 | 360/0.50 | 10.8 | 1.1 | 1.2 | 18.7 | 750 |
1×95 | 475/0.50 | 12.6 | 1.1 | 1.3 | 20.8 | 970 |
1×120 | 608/0.50 | 14.2 | 1.2 | 1.3 | 22.8 | 1220 |
1×150 | 756/0.50 | 15.8 | 1.4 | 1.4 | 25.5 | 1510 |
1×185 | 925/0.50 | 17.4 | 1.6 | 1.6 | 28.5 | 1850 |
1×240 | 1221/0.50 | 20.4 | 1.7 | 1.7 | 32.1 | 2400 |