ABC Cable-0.6/1KV
Grand Cable
Availability: | |
---|---|
Application
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
Applicable Standard
BS 7870-5
HD 626 S1
EN 60228
Cable Construction
Conductor: Stranded compacted circular aluminium
Insulation: Weather-Resistant Cross-Linked Polyethylene
Characteristics
Rated voltage (Uo/U): 0.6/1kV
Max. conductor temperature in normal operation: 90°C
Max. conductor temperature in short-circuit for 5s max duration: 250°C
Min. bend radius: 12 x D (D: overall diameter of cable)
Construction Parameters
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm^2 | mm | Kg/Km | Ω/Km | KN | A |
1x16+1x25 RM | 15.3 | 160 | 1.91 | 2.5 | 72 |
3x16+1x25 RM | 19 | 290 | 1.2 | 4 | 107 |
3x25+1x25 RM | 23.2 | 400 | 0.868 | 5.5 | 132 |
3x35+1x25 RM | 25.6 | 500 | 0.641 | 8 | 165 |
3x50+1x35 RM | 30 | 680 | 0.443 | 10.7 | 205 |
3x70+1x50 RM | 34.9 | 920 | 0.32 | 13.7 | 240 |
3x95+1x70 RM | 40.6 | 1270 | 0.253 | 18.6 | 290 |
3x120+1x70 RM | 44.1 | 1510 | 0.206 | 23.2 | 334 |
3x150+1x95 RM | 49.2 | 1870 | 0.164 | 28.7 | 389 |
3x185+1x120 RM | 54.9 | 2340 | 0.125 | 37.2 | 467 |
3x25+1x25+1x16 RM | 23.2 | 470 | 1.91 | 2.5 | 72 |
3x35+1x25+1x16 RM | 25.6 | 560 | 1.2 | 4 | 107 |
3x50+1x35+1x16 RM | 30 | 740 | 0.868 | 5.5 | 132 |
3x70+1x50+1x16 RM | 34.9 | 980 | 0.641 | 8 | 165 |
3x95+1x70+1x16 RM | 40.6 | 1330 | 0.443 | 10.7 | 205 |
3x120+1x70+1x16 RM | 44.1 | 1580 | 0.32 | 13.7 | 240 |
3x150+1x95+1x16 RM | 49.2 | 1940 | 0.206 | 23.2 | 334 |
3x185+1x120+1x16 RM | 54.9 | 2410 | 1.91 | 2.5 | 72 |
Application
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
Applicable Standard
BS 7870-5
HD 626 S1
EN 60228
Cable Construction
Conductor: Stranded compacted circular aluminium
Insulation: Weather-Resistant Cross-Linked Polyethylene
Characteristics
Rated voltage (Uo/U): 0.6/1kV
Max. conductor temperature in normal operation: 90°C
Max. conductor temperature in short-circuit for 5s max duration: 250°C
Min. bend radius: 12 x D (D: overall diameter of cable)
Construction Parameters
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm^2 | mm | Kg/Km | Ω/Km | KN | A |
1x16+1x25 RM | 15.3 | 160 | 1.91 | 2.5 | 72 |
3x16+1x25 RM | 19 | 290 | 1.2 | 4 | 107 |
3x25+1x25 RM | 23.2 | 400 | 0.868 | 5.5 | 132 |
3x35+1x25 RM | 25.6 | 500 | 0.641 | 8 | 165 |
3x50+1x35 RM | 30 | 680 | 0.443 | 10.7 | 205 |
3x70+1x50 RM | 34.9 | 920 | 0.32 | 13.7 | 240 |
3x95+1x70 RM | 40.6 | 1270 | 0.253 | 18.6 | 290 |
3x120+1x70 RM | 44.1 | 1510 | 0.206 | 23.2 | 334 |
3x150+1x95 RM | 49.2 | 1870 | 0.164 | 28.7 | 389 |
3x185+1x120 RM | 54.9 | 2340 | 0.125 | 37.2 | 467 |
3x25+1x25+1x16 RM | 23.2 | 470 | 1.91 | 2.5 | 72 |
3x35+1x25+1x16 RM | 25.6 | 560 | 1.2 | 4 | 107 |
3x50+1x35+1x16 RM | 30 | 740 | 0.868 | 5.5 | 132 |
3x70+1x50+1x16 RM | 34.9 | 980 | 0.641 | 8 | 165 |
3x95+1x70+1x16 RM | 40.6 | 1330 | 0.443 | 10.7 | 205 |
3x120+1x70+1x16 RM | 44.1 | 1580 | 0.32 | 13.7 | 240 |
3x150+1x95+1x16 RM | 49.2 | 1940 | 0.206 | 23.2 | 334 |
3x185+1x120+1x16 RM | 54.9 | 2410 | 1.91 | 2.5 | 72 |